        DR5200-FMCW雷達液位計的詳細資料

        DR5200-FMCW雷達液位計

        Overview
        The radar solution for solids
        This device is a non-contact Radar (FMCW) Level Meter for distance, level, volume and mass measurement of powders, granulates and other solids. It gives a more stable measurement than pulse radar and is well suited to dusty process conditions. The device can operate at very low and very high process temperatures as long as the process connection temperature limits are observed.

        Features DR5200-FMCW雷達液位計
        • One converter for all antenna types (PTFE drop, PP drop and metallic horn)
        • The only guarantee for measuring accuray in dusty conditions
        • Uses a unique drop antenna design for very dusty atmospheres
        •  ±0.12 in (±3mm) standard accuracy
        •  PP (Polypropylene) or PTFE drop antenna: its shape prevents product build-up in dusty applications 
        •  Operates up to a flange temperature of 390° F (200° C) and 580 psig (40 bar)
        •  Measuring range up to 260 ft (80 m)
        •  Antenna can be extended to suit any nozzle length
        •  PACTware and DTMs included as standard
        •  Optional second current output
        •  Directly-accessible graphic touchscreen/wizard (option)
        •  An installation wizard specifically for solids that permits the instrument to measure uneven surfaces accuray

        Industries 
        •  Minerals & Mining
        •  Chemical
        •  Food
        •  Iron, Steel & Metals
        •  Pulp & Paper

        Applications
        •  Storage
        •  Silos
        •  Hoppers

        • The following data is provided for general applications. If you require data that is more relevant to your specific ap- plication, please contact us or your local sales office.

        • Additional information (certificates, special tools, software,...) and complete product documentation can be down- loaded free of charge from the website (Download Center).

        Measuring system

        Measuring principle

        2-wire loop-powered level transmitter; K-band (24...26 GHz) FMCW radar

        Application range

        Level measurement of powders and granulates

        Primary measured value

        Δf (change in frequency) between the emitted and received signal

        Secondary measured value

        Distance, level, volume, mass and reflectivity

        Design

        Construction

        The measurement system consists of a measuring sensor (antenna) and a signal converter which is only available in a compact version

        Standard

        Antenna purging system for horn antenna (supplied with a ¼ NPTF connection – for horn antenna only)

        Options

        Integrated LCD display with sun cover -4…+140°F (-20..+60°C); if the ambient temperature is not in these limits, the display switches off

        2nd current output

        PTFE/PP flange plate protection (for drop antenna without antenna extensions only)

        Distance piece for process temperature:  +300...+390°F (+150...+200°C)

        Accessories

        Weather protection

         

        Antenna extensions of 4.1 in (105mm) length. Maximum length for drop antenna versions: 20.7 in (525mm)

         

        2° slanted PP flange (for all antennas)

        Max. measuring range

        260 ft (80 m)

         

        Depends on the antenna option, dielectric constant of the product and installation type. Refer also to "Antenna selection".

        Min. tank height

         8 in (0.2 m)

        Dead zone

        Antenna extension length+antenna length, 12 in (+ 0.3 m)

        Beam angle of antenna

        Horn / Sheet metal horn DN80 / 3 in: 10°

         

        Horn / Sheet metal horn DN100 / 4 in: 8°

         

        Sheet metal horn DN150 / 6 in: 8°

         

        Sheet metal horn DN200 / 8 in: 8°

         

        drop DN80 / 3 in: 8°

         

        drop DN150 / 6 in: 4°

        Display and user interface

        Display

        LCD display

        9 lines, 160 × 160 pixels in 8-step grayscale with 4-button keypad

        Interface languages

        English, German, French, Italian, Spanish, Portuguese, Japanese, Simplified
        Chinese and Russian

        Measurement accuracy

        Resolution

        0.04 in (1mm)

        Repeatability

        ±0.04 in (±1mm)

        Accuracy

        ±0.12 in (±3mm), when distance < 33 ft (10 m);
        ±0.03% of measured distance, when distance > 33 ft (10 m)

        Reference conditions acc. to EN 60770

        Temperature

         +70°F ±10°F (+20°C ±5°C)

        Pressure

         14.69 psia ±0.29 psi (1013 mbara ±20 mbar)

        Relative air humidity

        60% ±15%

        Target

        Metal plate in an anechoic chamber

        Operating conditions

        Temperature

        Ambient temperature

        -40…+175°F (-40…+80°C) (according to the temperature limits of the gasket material. Refer to "Materials" in this table.)
        Ex: see supplementary operating instructions or approval certificates

        Storage temperature

        -40…+185°F (-40…+85°C)

        Flange temperature

        Horn / Sheet metal horn antenna: 
        Standard: -58…+300°F (-50…+150°C) Option:  -58…+390°F (-50…+200°C)
        (the process connection temperature must agree with the temperature limits of the gasket material. Refer to "Materials" in this table.)
        Ex: see supplementary operating instructions or approval certificates

         

        drop antenna (PTFE):
        -58…+300°F  (-50…+150°C) (the process connection temperature must agree with the temperature limits of the gasket material. Refer to "Materials" in this table.) Ex: see supplementary operating instructions or approval certificates

         

        drop antenna (PP):
        -40…+210°F  (-40…+100°C) (the process connection temperature must agree with the temperature limits of the gasket material. Refer to "Materials" in this table.) Ex: see supplementary operating instructions or approval certificates

        Pressure

        Operating pressure

        drop antenna (PP):
        -14.5…232 psig (-1…16 barg);
        subject to process connection used and flange temperature

         

        drop antenna (PTFE):
        -14.5…580 psig (-1…40 barg);
        subject to process connection used and flange temperature

         

        Horn / Sheet metal horn antenna: Standard:
        -1…40 barg / -14.5…580 psig;
        subject to process connection used and flange temperature

        Other conditions

        Dielectric constant (?r)

        ≥1.5

        Vibration resistance

        IEC 60068-2-6 and EN 50178 (10...57Hz: 0.075mm / 57...150Hz:1g)

        Protection category

        IP 66/67 equivalent to NEMA type 4X (housing) and type 6P (antenna)

        Maximum rate of change

         33 ft / minute (10 m / minute)

        Installation conditions

         

        Process connection size

        The nominal diameter (DN) should be equal to or larger than the antenna diameter.

        If the nominal diameter (DN) is smaller than the antenna, either: – provide the means to adapt the device to a larger process connection on the silo (for example, a plate with a slot), or – use the same process connection, but remove the antenna from the device before installation and fit it from inside the silo

        Process connection position

        Make sure that there are not any obstructions directly below the process connection for the device.

        Dimensions and weights

        Refer to "Technical data: Dimensions and weights".

        Materials

        Housing

        Standard: Polyester-coated aluminium

        Option: Stainless steel (1.4404 / 316L) 1

        Wetted parts, including antenna

        Horn / Sheet metal horn antenna: Stainless steel (1.4404 / 316L)

        drop antenna: PTFE; PP – a PP or PTFE flange plate protection option is also available

        Process connection

        Stainless steel (1.4404 / 316L) – a PP or PTFE flange plate protection option is also available for the drop antenna

        Gaskets (and o-rings for the sealed antenna extension option)

        PTFE drop antenna:
        FKM/FPM -40…+300°F (-40…+150°C); Kalrez® 6375  -4…+300°F (-20…+150°C); EPDM -58…+300°F (-50°C…+150°C) 2

        PP drop antenna:
        FKM/FPM  -40…+210°F (-40…+100°C); Kalrez® 6375 -4…+210°F (-20…+100°C); EPDM -40…+210°F (-40°C…+100°C) 2

        Horn / Sheet metal horn antenna:
        FKM/FPM -40…+390°F (-40…+200°C); Kalrez® 6375 -4…+390°F (-20…+200°C); EPDM -58…+300°F (-50°C…+150°C) 2

        Feedthrough

        Standard: PEI -58...+390°F (-50...+200°C) – max. range. The feedthrough temperature limits must agree with the temperature limits of the gasket material and antenna type. If the distance piece option is not attached, the maximum temperature is 300°F (150°C).

        Option: Metaglas® -22...+390°F (-30...+200°C) – max. range. The feedthrough temperature limits must agree with the temperature limits of the gasket material and antenna type. If the distance piece option is not attached, the maximum temperature is 300°F (150°C). 3

        Weather protection (Option)

        Stainless steel (1.4301 / 304)

        Process connections

        Thread

        G 1½ (ISO 228); 1½ NPT (ASME B1.20.1)

        Flange version

        EN 1092-1

        DN80 in PN40, DN100…200 in PN16 or PN40 (Form B1); others on request

        ASME B16.5

        3 in…8 in in 150 lb RF, 3 in...4 in in 300 lb RF; others on request

        JIS B2220

        80…100A in 10K; others on request

        Other

        Others on request

        Electrical connections

        Power supply

        Terminals output 1 – Non-Ex / Ex i:
        14…30 VDC; min./max. value for an output of 22mA at the terminal

        Terminals output 1 – Ex d:
        20…36 VDC; min./max. value for an output of 22mA at the terminal

        Terminals output 2 – Non-Ex / Ex i / Ex d:
        10…30 VDC; min./max. value for an output of 22mA at the terminal (additional power supply needed – output only)

        Cable entry

        M20×1.5; ½ NPT

        G ½ (not for FM- and CSA-approved devices. Not for stainless steel housings.)

        M25×1.5 (for stainless steel housings only)

        Cable gland

        Standard: none

        Options: M20×1.5 (for non-Ex and Ex -approved devices with M20×1.5 and M25×1.5 cable entries); others are available on request

        Cable entry capacity (terminal)

        0.5…1.5mm²

        Input and output

        Current output

        Output signal
        (Output 1)

        4…20mA HART® or 3.8…20.5mA acc. to NAMUR NE 43 4

        Output signal
        (Output 2 - optional)

        4…20mA (no HART® signal) or 3.8…20.5mA acc. to NAMUR NE 43

        Resolution

        ±3 µA

        Temperature drift

        Typically 25 ppm/K

        Error signal

        High: 22mA; Low: 3.6mA acc. to NAMUR NE 43

        Approvals and certification

        CE

        This device fulfils the statutory requirements of the EC directives. The manufacturer certifies successful testing of the product by applying the CE mark.

        Explosion protection

         

        ATEX
        KEMA 04ATEX1218 X

        II 1 G, 1/2 G, 2 G Ex ia IIC T6...T3;

        II 1 D, 1/2 D, 2 D Ex iaD20or Ex iaD 20/21 or Ex iaD 21 IP6X T70°C...T95°C;

        II 1/2 G, 2 G Ex d[ia] IIC T6...T3;

        II 1/2 D, 2 D Ex tD[iaD] A21/20 or Ex tD[iaD] A21 IP6X T70°C...T95°C

        IECEx
        IECEx KEM 06.0025 X

        Ga Ex ia IIC T6…T3; Ex iaD20IP6X T70°C…T95°C;

        Ga/Gb Ex d[ia] IIC T6…T3; Ex tD[iaD] A21/20 IP6X T70°C…T95°C

        FM – Dual Seal-approved

        NEC 500

        XP-IS / Cl. I / Div. 1 / Gr. ABCD / T6-T1;

        DIP / Cl. II, III / Div. 1 / Gr. EFG / T6-T1;

        IS / Cl. I, II, III / Div. 1 / Gr. ABCDEFG / T6-T1;

        NI / Cl. I / Div. 2 / Gr. ABCD / T6-T1

        NEC 505

        Cl. I / Zone 0 / AEx d[ia] / IIC / T6-T1;

        Cl. I / Zone 0 / AEx ia / IIC / T6-T1;

        Cl. I / Zone 2 / AEx nA[ia] / IIC / T6-T1

        Hazardous (Classified) locationss, indoor/outdoor Type 4X and 6P, IP66, Dual Seal

        CSA – Dual Seal-approved

        CEC Section 18 (Zone ratings)

        Cl. I, Zone 1, Ex d, IIC (Antenna: Zone 0) T6;

        Cl. I, Zone 0, Ex ia, IIC T6;

        Cl. I, Zone 2, Ex nA, IIC T6

        CEC Section 18 and Annex J (Division ratings)

        XP-IS, Cl. I, Div. 2, Gr. ABCD; Cl. II, Div. 2, Gr. FG; Cl. III, Div. 2 T6;

        IS, Cl. I, Div. 1, Gr. ABCD; Cl. II, Gr. FG; Cl. III T6

        NEPSI GYJ091178/79

        Ex d ia IIC T3~T6 DIP A21/20 TA T70°C~T95°C IP6X;

        Ex ia IIC T3~T6 DIP A21/20 TA T70°C~T95°C IP6X

        DNV / INMETRO DNV 12.0043 X

        Ex ia IIC T6…T3 Ga; Ex ia IIIC T70°C...T95°C Da IP6X;

        Ex d [ia Ga] IIC T6...T3 Ga/Gb; Ex tb [ia Da] IIIC T70°C...T95°C Db IP6X

        KGS
        11-GA4BO-0325X
        11-GA4BO-0326X

        Ex ia IIC T6~T3; Ex iaD20IP6X T70°C~T95°C;

        Ex d[ia] IIC T6~T3; Ex tD[iaD] A21/20 IP6X T70°C~T95°C

        Other standards and approvals

        EMC

        Electromagnetic Compatibility Directive 2004/108/EC in conjunction with
        EN 61326-1 (2013)

        R & TTE

        Radio Equipment and ecommunications Terminal Equipment Directive
        1999/5/EC in conjunction with ESTI EN 302 372-1 (2011) and EN 302 372-2 (2011)

        FCC Rules

        Part 15

        Industry Canada

        RSS-210

        LVD

        Low-Voltage Directive 2006/95/EC in conjunction with EN 61010-1 (2001)

        CRN

        This certification is for all Canadian provinces and territories. For more data, refer to the website.

        NAMUR

        NAMUR NE 21 Electromagnetic Compatibility (EMC) of Industrial Process and
        Laboratory Control Equipment

        NAMUR NE 43 Standardization of the Signal Level for the Failure Information of
        Digital Transmitters

         

         

         

        1 This option is not available for FM- or CSA-approved devices

         

        2 Kalrez® is a registered trademark of DuPont Performance Elastomers L.L.C.

         

        3 Metaglas® is a registered trademark of Herberts Industrieglas, GMBH & Co., KG

         

        4 HART® is a registered trademark of the HART Communication Foundation

         

        該產品由深圳市蘑菇官方网站进入IOS電子科技有限公司提供,銷售商地址位於深圳市南山區前海路振業國際商務中心1206。請您仔細閱讀產品使用說明書,正確使用。

        如果想試用該產品,請本單位:

         

        蘑菇官方网站进入IOS電子主要銷售通信設備、儀器儀表、電力設備、熱工儀表、校準設備及工具配件。有多功能多產品校準器、電能功率校準器、活塞式成人蘑菇视频免费观看(氣體、高壓、液體、真空)、多功能電氣安全校準器、示波器、頻率計、萬用表、阻抗蘑菇网站成人、功率計、LCR數字電橋、音頻蘑菇网站成人、電容測試儀、電感測試儀、安規測試儀、直流電阻測試儀、網絡蘑菇网站成人、頻譜儀、任意波形發生器、溫度校準儀、數字測溫儀、信號發生器、電源、電子負載、綜合測試儀、信號源、濾波器測試儀、材料試驗機、溫度傳感器、熱像儀、變壓器測試儀、噪聲源、視頻蘑菇网站成人、過程校準儀、溫度巡檢儀、超級測溫電橋、黑體爐、射頻導納物位開關、多點物位開關、音叉開關、射頻導納連續物位計、雷達液位計、超聲波液位計、油中水含量蘑菇网站成人、液位測量係統、磁致伸縮液位計、非接觸固體雷達、壓力傳感器、過程表、壓力變送器、氣動控製器、高純壓力開關、隔膜片、衝液表、計量表膜片密封、材料實驗機、食品質構儀、硬度實驗機、數字測力計、PETPLUS特性粘度儀、布氏光學掃描係統、洛氏布硬度實驗機、全自動顯微硬度試驗機、布氏硬度試驗機、電動試驗平台、單柱材料試驗係統、雙柱材料試驗係統、浮球活塞成人蘑菇视频免费观看、船用溫度壓力校驗儀、點位測量係統、超聲波開關、油/水界麵開關、在線流體檢測開關、多點開關、平板開關、浮頂罐溢出保護開關、空氣加熱器、織物加熱套、電加熱帶、矽橡膠加熱毯、圓桶加熱器、IBC加熱器、氣體加熱器、灰鬥加熱係統、自限溫電伴熱帶、恒功率電伴熱帶、恒功率電伴熱帶、覆套式電阻加熱器、電阻絲、溫度控製器、危險環境加熱器及控製、複合材料修補儀、真空修補/處理平台、A320升降舵無損檢驗包;靜電放電幹擾模擬器、雷擊浪湧幹擾模擬器、周波跌落模擬器、輻射抗擾度係統、脈衝群幹擾模擬器、傳導抗擾度測試係統、傳導幹擾測試係統、輻射幹擾測試係統等儀器。 

        掃一掃

        歡迎關注蘑菇官方网站进入IOS網站平台

        聯係蘑菇官方网站进入IOS

        名稱:極儀蘑菇官方网站进入IOS

        客服電話:0755-23964199,86564199

        E-mail:service@1001718.com

        傳真:0755-23964199

        郵編:518052

        Copyright © 2024-2025 深圳市蘑菇官方网站进入IOS電子科技有限公司 版權所有網站地圖 ICP備案號:粵ICP備22107523號
        極儀蘑菇官方网站进入IOS 製作維護

        0755-23964199
        0775-86564199

        微信掃一掃,給我發消息吧

         
        網站地圖