1. 蘑菇官方网站进入IOS,蘑菇网站成人,蘑菇视频APP污,成人蘑菇视频免费观看

        您當前的位置:>> 首頁 > 產品中心 > 紅外熱成像儀 > 壓力和液位 >> 橫河電機EJX115A壓力變送器115A

        產品搜索:
        請在下列輸入框內輸入您要查找的產品名稱。

        產品目錄
        產品中心
        打印 字體縮放

        橫河電機EJX115A壓力變送器115A的詳細資料

        橫河電機EJX115A壓力變送器

        The high performance differential pressure transmitter EJX110A features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam ? ow as well as liquid level, density and pressure. EJX110A outputs a 4 to20mA DC signal corresponding to the measured differential pressure. 
        Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remoy monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications, diagnostics and optional status output for pressure high/low alarm. The multi-sensing technology provides the advanced diagnostic function to detect such abnormalities as an impulse line blockage or heat trace breakage. FOUNDATION Fieldbus and PROFIBUS PA protocol types are also available. All EJX series 
        models in their standard con? guration, with the exception of the Fieldbus and PROFIBUS types, are certi? ed by TÜV as complying with SIL 2 for safety requirement.

        ? STANDARD SPECIFICATIONS
        Refer to GS 01C25T02-01EN for Fieldbus 
        communication type and GS 01C25T04-01EN for 
        PROFIBUS PA communication type for the items 
        marked with “◊.”
        □ SPAN AND RANGE LIMITS
        Measurement
        Span/Range kPa inH2O
        (/D1)
        mbar 
        橫河電機EJX115A壓力變送器
        (/D3)
        mmH2O
        (/D4)
        F*
        Span 0.1 to 5 0.4 to201 to 50 10 to 500
        Range -5 to 5 -20 to20-50 to 50 -500 to 
        500
        L*
        Span 0.1 to 10 0.4 to 40 1 to 100 10 to 1000
        Range -10 to 10 -40 to 40 -100 to 
        100
        -1000 to  

        1000
        M
        Span 0.5 to 100 2 to 400 5 to 1000 50 to 
        10000
        Range -100 to 
        100
        -400 to 
        400
        -1000 to 
        1000 

        -10000 to 
        10000
        H
        Span 2.5 to 500 10 to 2000 25 to 5000 0.025 to 5 
        kgf/cm2
        Range -500 to 
        500
        -2000 to 
        2000
        -5000 to 
        5000
        -5 to 5 
        kgf/cm2
        V
        Span 0.07 to 14 
        MPa
        10 to 2000 
        psi
        0.7 to 140 
        bar
        0.7 to 140 
        kgf/cm2
        Range -0.5 to 14 
        MPa
        -71 to 
        2000
        -5 to 140 
        bar
        -5 to 140 
        kgf/cm2
        *: F capsule is applicable for wetted parts material 
        code S.
         L capsule is applicable for wetted parts material 
        code other than S.

        PERFORMANCE SPECIFICATIONS
        Zero-based calibrated span, linear output, wetted 
        parts material code S and silicone oil, unless 
        otherwise mentioned.
        For Fieldbus and PROFIBUS PA communication 
        types, use calibrated range instead of span in the 
        following specifi cations.
        Specifi cation Conformance
        EJX series ensures specifi cation conformance to at 
        least ±3σ.
        Reference Accuracy of Calibrated Span
        (includes terminal-based linearity, hysteresis, and 
        repeatability)
        Measurement span F
        Reference
        accuracy
        X ≤ span ±0.04% of Span
        X > span ±(0.015+0.01 URL/span)% of Span
        X 2 kPa (8 inH2O)
        URL
        (upper range limit) 5 kPa (20 inH2O)
        Measurement span M
        Reference
        accuracy
        X ≤ span ±0.04% of Span
        X > span ±(0.002+0.0019 URL/span)% of Span
        X 5 kPa (20 inH2O)
        URL
        (upper range limit) 100 kPa (400 inH2O)
        Measurement span H
        Reference
        accuracy
        X ≤ span ±0.04% of Span
        X > span ±(0.005+0.0049 URL/span)% of Span
        X 70 kPa (280 inH2O)
        URL
        (upper range limit) 500 kPa (2000 inH2O)

        Measurement span V
        Reference
        accuracy
        X ≤ span ±0.04% of Span
        X > span ±(0.005+0.00125 URL/span)% of Span
        X 500 kPa (2000 inH2O)
        URL
        (upper range limit) 14 MPa (2000 psi)
        Square Root Output Accuracy
        The square root accuracy is a percent of flow span.
        Output Accuracy
        50% or Greater Same as reference accuracy
        50% to Dropout point Reference accuracy × 50
        Square root output (%)
        Ambient Temperature Effects per 28°C (50°F) 
        Change
        Capsule Effect
        F
        M
        H, V
        ±(0.055% Span+0.18% URL)
        ±(0.04% Span+0.009% URL)
        ±(0.04% Span+0.0125% URL)
        ? Total Probable Error (M capsule)
        ±0.12% of Span @1:1 to 5:1 Rangedown
        Total probable error, known as a measure of the total 
        performance of the transmitters under the condition of 
        fixed line presurre.
        Total Probable Error=± E1
        2+E2
        2+E3
        2
        E1: Reference Accuracy of Calibrated Span
        E2: Ambient Temperature Effects per 28°C change
        E3: Static Span Effects per 6.9 MPa change
        ? Total Accuracy (M capsule)
        ±0.12% of Span @1:1 Rangedown
        ±0.25% of Span @ 5:1 Rangedown
        Total accuracy is a comprehensive measure of 
        transmitter total performance, covering all major 
        factors in actual installation, that cause errors in 
        measurement.
        As a standard measure, YOKOGAWA uses this to 
        evalsuate transmitter performance.
        Total Accuracy=± E1
        2+E2
        2+(E3+E4)
        2+E5
        2
        E1: Reference Accuracy of Calibrated Span
        E2: Ambient Temperature Effects per 28°C change
        E3: Static Span Effects per 6.9 MPa change
        E4: Static Zero Effects per 6.9 MPa change
        E5: Overpressure Effects upto overpressure 25MPa
        Not only a day-to-day changes in temperature can 
        affect the measurement and lead to unnoticed errors; 
        fluctuaion of line pressure, incorrect operation of 
        three/five valve manifold leading to over-pressure 
        events, and other phenomena can have the similar 
        result. Total Accuracy factors in such changes and 
        errors and provides much comprehensive and 
        practical determination of how a transmitter will 
        perform under actual plant operation.

        Static Pressure Effects per 6.9 MPa (1000 psi) 
        Change
         Span Effects
        F, M, H and V capsules
        ±0.075% of span
         Effect on Zero
        Capsule Effect
        F
        M
        H, V
        ±0.1% URL
        ±0.02% URL
        ±0.028% URL
        Overpressure Effects
        Overpressure condition: up to maximum working 
        pressure
        M, H and V capsules
        ±0.03% of URL
        Stability (All normal operating condition, including 
        overpressure effects)
        M, H and V capsules
        ±0.1% of URL per 10 years
        F capsule
        ±0.1% of URL per one year
        Power Supply Effects(Output signal code D, E 
        and J)
        ±0.005% per Volt (from 21.6 to 32 V DC, 350Ω)
        Vibration Effects
        Amplifier housing code 1 and 3:
        Less than 0.1% of URL when tested per the 
        requirements of IEC60770-1 field or pipeline 
        with high vibration level (10-60Hz, 0.21mm 
        displacement/60-2000Hz 3 g)
        Amplifier housing code 2:
        Less than ±0.1% of URL when tested per the 
        requirements of IEC60770-1 field with general 
        application or pipeline with low vibration level (10-60 
        Hz 0.15mm displacement /60-500Hz 2g)
        Mounting Position Effects
        Rotation in diaphragm plane has no effect. Tilting 
        up to 90 degree will cause zero shift up to 0.4 kPa 
        (1.6 inH2O) which can be corrected by the zero 
        adjustment.
        Response Time (Differential pressure) “◊”
        90 ms for Wetted Parts material code S except for 
        Measuring span code F. 150 ms for Wetted Parts 
        Material Code H, M, T, A, B, D and W or Measuring 
        span code F.
        When amplifier damping is set to zero and including 
        dead time of 45 ms (nominal)
        Static Pressure Signal Range and Accuracy 
        (For monitoring via communication or on 
        indicator. Includes terminal-based linearity, 
        hysteresis, and repeatability)
         Range
        Upper Range Value and Lower Range Value of the 
        statice pressure can be set in the range between 0 
        and Maximum Working Pressure(MWP). The upper 
        range value must be greater than the lower range 
        value. Minimum setting span is 0.5 MPa(73 psi).
        Measuring either the pressure of high pressure side 
        or low pressure side is user-selectable.

         

        該產品由深圳市蘑菇官方网站进入IOS電子科技有限公司提供,銷售商地址位於深圳市南山區前海路振業國際商務中心1206。請您仔細閱讀產品使用說明書,正確使用。

        如果想試用該產品,請以下單位: 

        蘑菇官方网站进入IOS電子主要銷售通信設備、儀器儀表、電力設備、熱工儀表、校準設備及工具配件。

        掃一掃

        歡迎關注蘑菇官方网站进入IOS網站平台

        聯係蘑菇官方网站进入IOS

        名稱:極儀蘑菇官方网站进入IOS

        客服電話:0755-23964199,86564199

        E-mail:service@1001718.com

        傳真:0755-23964199

        郵編:518052

        Copyright © 2024-2025 深圳市蘑菇官方网站进入IOS電子科技有限公司 版權所有網站地圖 ICP備案號:粵ICP備22107523號
        極儀蘑菇官方网站进入IOS 製作維護

        0755-23964199
        0775-86564199

        微信掃一掃,給我發消息吧

         
        網站地圖